bank 2 NISSAN 350Z 2007 Z33 Engine Control Owner's Guide

Page 177 of 720

DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-177
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 November2007 350Z
BANK 2
TBWT1620E

Page 178 of 720

EC-178
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2006 November2007 350Z
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
33 PU/WHeated oxygen sensor 2
heater (bank 2)[Engine is running]
Engine speed: Below 3,600 rpm after the
following conditions are met.
–Engine: After warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load.0 - 14V
[Ignition switch: ON]
Engine stopped
[Engine is running]
Engine speed: Above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
80 R/YHeated oxygen sensor 2
(bank 2)[Engine is running]
Revving engine from idle to 3,000 rpm
quickly after the following conditions are
met.
–Engine: After warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load.0 - 1.0V
84 GSensor ground
Heated oxygen sensor 2,
Engine coolant temperature
sensor, Engine oil tempera-
ture sensor)[Engine is running]
Warm-up condition
Idle speed0V
PBIB3545E

Page 180 of 720

EC-180
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2006 November2007 350Z
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S2 terminal 2 and ground with
CONSULT-III or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
15A fuse
Harness for open or short between heated oxygen sensor 2 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
1. Heated oxygen sensor 2 (bank 2) 2. Heated oxygen sensor 2 (bank 2)
harness connector3. Heated oxygen sensor 2 (bank 1)
4. Heated oxygen sensor 2 (bank 1)
harness connector
:Vehicle front
Voltage: Battery voltage
PBIB3502E
MBIB0186E

Page 181 of 720

DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-181
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 November2007 350Z
4. CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 2 HEATER
Refer to EC-181, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-141, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionNBS0004P
HEATED OXYGEN SENSOR 2 HEATER
1. Check resistance between HO2S2 terminals as follows.
2. If NG, replace heated oxygen sensor 2.
CAUTION:
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system
threads using Oxygen Sensor Thread Cleaner tool J-43897-
18 or J-43897-12 and approved anti-seize lubricant.
DTCTe r m i n a l s
Bank
ECM Sensor
P0037, P0038 17 3 1
P0057, P0058 33 3 2
Continuity should exist.
Terminal No. Resistance
2 and 3 3.4 - 4.4 Ω [at 25°C (77°F)]
1 and 2, 3, 4
∞ Ω
(Continuity should not exist)
4 and 1, 2, 3
PBIB3310E

Page 183 of 720

DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-183
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 November2007 350Z
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component DescriptionNBS000BR
Intake valve timing control solenoid valve is activated by ON/OFF
pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil
amount and direction of flow through intake valve timing control unit
or stops oil flow.
The longer pulse width advances valve angle.
The shorter pulse width retards valve angle.
When ON and OFF pulse widths become equal, the solenoid valve
stops oil pressure flow to fix the intake valve angle at the control
position.
CONSULT-III Reference Value in Data Monitor ModeNBS000BS
Specification data are reference values.
On Board Diagnosis LogicNBS000BT
DTC Confirmation ProcedureNBS000BU
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and
wait at least 10 seconds before conducting the next test.
WITH CONSULT-III
1. Start engine and let it idle for 5 seconds.
2. Check 1st trip DTC.
3. If 1st trip DTC is detected, go to EC-188, "
Diagnostic Procedure" .
WITH GST
Following the procedure “WITH CONSULT-III” above.
PBIB1842E
MONITOR ITEM CONDITION SPECIFICATION
INT/V SOL(B1)
INT/V SOL(B2)
Engine: After warming up
Shift lever: P or N (A/T), Neutral
(M/T)
Air conditioner switch: OFF
No loadIdle 0% - 2%
2,000 rpm Approx. 0% - 50%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0075
0075
(Bank 1)
Intake valve timing control
solenoid valve circuitAn improper voltage is sent to the ECM
through intake valve timing control solenoid
valve.
Harness or connectors
(The intake valve timing control solenoid
valve circuit is open or shorted.)
Intake valve timing control solenoid valve P0081
0081
(Bank 2)

Page 184 of 720

EC-184
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2006 November2007 350Z
Wiring DiagramNBS000BV
BANK 1
TBWT1621E

Page 185 of 720

DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-185
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 November2007 350Z
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-III.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
18 W/GIntake valve timing control
solenoid valve (bank 1)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm7 - 12V
24 BR/YECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
125 R Power supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB3546E

Page 186 of 720

EC-186
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2006 November2007 350Z
BANK 2
TBWT1622E

Page 187 of 720

DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-187
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2006 November2007 350Z
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-III.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
24 BR/YECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
29 G/WIntake valve timing control
solenoid valve (bank 2)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
Engine speed: 2,000 rpm7 - 12V
125 R Power supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB3546E

Page 188 of 720

EC-188
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2006 November2007 350Z
Diagnostic ProcedureNBS000BW
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect intake valve timing control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between intake valve timing control solenoid
valve terminal 2 and ground with CONSULT-III or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
Harness for open or short between intake valve timing control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 18 (bank 1) or 29 (bank 2) and intake valve timing con-
trol solenoid valve terminal 1. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
1. Exhaust valve timing control magnet
retarder (bank 1) harness connector2. Intake valve timing control solenoid
valve (bank 1) harness connector3. Intake valve timing control solenoid
valve (bank 2) harness connector
4. Exhaust valve timing control magnet
retarder (bank 2) harness connector
Voltage: Battery voltage
PBIB3508E
PBIB0192E
Continuity should exist.

Page:   < prev 1-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 ... 250 next >